FTR-210R Firmware

Changelog

V1.7.7

  • Added NTP server (SW license required)
  • Non-stop Mode (SCPI only) – measurement that runs forever (until explicitly interrupted) (for opt. 230)
  • Timestamps fetched via SCPI now keep picoseconds numeric resolution even for very long measurements (for opt. 230)
  • Calculate PDEV for Smart Frequency & Smart Period Average (opt. 161F & 230) and for Smart Frequency Offset (opt. 161F & 152F & 230)
  • Improved license importing information message
  • Self-tests are now run after importing new licenses.
  • Fix: setting time zone via SCPI is now possible
  • Misc other fixes

V1.6.12

  • Added extended SW license consistency checks in the instrument’s start-up self-testing routine

V1.6.7

  • Fixed a bug in Network settings page

V1.6.6

  • FTR-210R: updated internal calibration report and dedicated measurements
  • Support for SCPI over USB (via RNDIS – Ethernet over USB)
  • Instrument is now accessible via link-local address in the form: pendulum-<model name (with non-alphanumeric symbols filtered out)>-<serial number>.local. E.g.: pendulum-cnt104r-123456.local
  • Allow instrument network discovery by LXI Discovery Tools and avahi-browse tools
  • Bug fix: unresponsive user interface in case of no signal and short measurement timeout

V1.5.10

  • Improved individual measurement speed when using Timeout with Timeout Time below 200 ms (for Opt 230)
  • Fix: pressing Protect button (Shield icon) in Presets screen without any preset selected lead to full user partition write protection (not possible to save/delete files)

V1.5.9

  • Opt 161F, ADEV Graph
  • Enabled ADEV calculation when MATH formula K * X + L is selected (useful when measuring downconverted signals)
  • Opt 214 (2 x 100 MHz, 2 x 10 MHz) support
  • Opt 133F IRIG-B DCLS via Pulse Output (requires Opt 132F)
  • Remote Alarms via SNMP support
  • Alarms for Hold-over and GNSS fix loss conditions
  • Improved calculations for long measurements for TIE and Timestamps functions
  • New Graph Cursors/Zoom function (button to auto-set cursors to min/max, zoom to cursors)
  • Fix for “When not measuring” Oscilator Disciplining Mode
  • Fixed saving debug data for Opt 220 Traceability
  • Fixes for the Opt 220 Traceability screen
  • Enabled Voltage measurements for Opt 220 Traceability
  • Added raw DAC mean and standard deviation to Opt 220 Traceability Calibration Report
  • Fix saving Frequency Ratio measurements to file
  • Miscellaneous stability improvements
  • Fixes for Graph Cursors/Zoom function
  • Improved Pulse Width measurement when Opt 220 Traceability is installed
  • Fixes for PPS Output offset handling

 

 